- Portable Multi-parameter Patient Monitor is adaptable to adult, pediatric and neonatal usage.
- It can monitor vital signals as ECG,Respiratory Rate,SpO2,NIBP,TEMP and IBP.Monitored date can be displayed, reviewed, stored and printed.
- 12.1" high resolution color TFT LCD touch screen,easy and convenient to operate.
- Modular design,the modules can be configured and combined flexibly and conveniently, meets the requirements of different departments on different parameters.
- PVI (Pleth Variability Index)
- USB support PDF file export.
- Central station support Nurse Call by wire/wireless network.
- Digital SpO2 with excellent performance.
- 720 hours trend data and 12 hours of all waveforms.
- 16 languages include: English, French, German, Spanish, Portuguese etc.
- Widely used in the Department of internal medicine,operation room,obstetrics and Gynecology, pediatrics, emergency center,ICU,CCU.
Standard parameters:ECG, RESP, NIBP, SPO2, TEMP, PR.
Optional:Dual IBP , CO2 , CSM module , Gas
ECG
Lead mode:5 Leads, I, II, III, AVR, AVL, AVF, V
Gain:0.25, ´0.5, ´1, ´2
Heart rate:
Adult:15 ~ 300 bpm
Neonatal/Pediatric:15 ~ 350 bpm
Accuracy:1%
Resolution:1 bpm
Sensitivity:> 200 μV P-P
Differential Input Impedance:> 5 M ohm
Electrode offset potential:300mV
Leakage Current:< 10 μA
PACE pulse detect
Range:±2~±700mV
Width:0.1~2ms
rise time:10~100µs
PACE pulse rejection
Range:±2~±700mV
Width:0.1~2ms
rise time:10~100µs
ST measurement
Range;-2.0 ~ +2.0 mV
Accuracy:-0.8mV~+0.8mV:
±0.02mV or ±10%, which is greater
Respiration
Method:Impedance between RA-LL or RA-LA
Differential Input Impedance:>2.5 M ohm
Respiration Impedance Range:0.3~3Ω
Base Impedance Range:200Ω-2000Ω
Bandwidth:0.3 ~ 2 Hz
Gain:×0.25,×0.500,×1,×2,×4
Respiration Rate
Measurement Range
Adult:0 ~ 120 BrPM
Neonatal / Pediatric: 0 ~ 150 BrPM
Resolution: 1 BrPM
Accuracy
0~6 BrPM: unspecified
7~150 BrPM: ±2 BrPM or ±2%, the greater
Inspiriting current:< 300 µA RMS max
Apnea Alarm:10 ~ 40 s
Temperature
Channel:1
Measure and Alarm Range:0 ~ 50 °C
Resolution:0.1°C
Accuracy:± 0.2℃
NIBP
Pulse Rate Range:40 ~ 240 bpm
Measure and Alarm Range
Adult Mode
SYS:40 ~ 280 mmHg
DIA:10 ~ 220 mmHg
MEAN:20 ~ 240 mmHg
Pediatric Mode
SYS:40 ~ 220 mmHg
DIA :0 ~ 160 mmHg
MEAN:20 ~ 170 mmHg
Neonatal Mode
SYS:35 ~ 135 mmHg
DIA:10 ~ 100 mmHg
MEAN:20 ~ 110 mmHg
Static pressure accuracy:3mmHg
Resolution:1mmHg
Accuracy
Maximum Mean error:5mmHg
Maximum Standard deviation:8mmHg
Over pressure Protection
Adult:300 mmHg
Pediatric:240 mmHg
Neonatal:150 mmHg
SpO2
Measurement Range:0 ~ 100 %
Resolution:1 %
Accuracy
2 % for 70% ~ 100%
0% ~ 69% unspecified
Pulse Rate
Measure and Alarm Range:20~250bpm
Resolution:1bpm
Accuracy:3bpm